KIEN3016M/3024M Industrial Ethernet Switch User’s Manual
-64-
hubs. In the direct connection wire, pin 1, 2, 3 and 6 are at the same end of the
cable and are connected to the pin 1, 2, 3 and 6 at the other end of the connection
cable. If it is necessary to connect to the switches or hubs with MDI-X port, it
needs to use the crossover wire. For the concrete condition on the
10Base-T/100Base-TX pin assignment, refer to table A-1.
Table A-1 10Base-T/100Base-TX Pin Assignment
Pin
MDI-X signal name
MDI signal name
1
Receiving data
+
(RD+)
Output data + (TD+)
2
Receiving data - (RD-)
Output data - (TD-)
3
Output data + (TD+)
Receiving data
+
(RD+)
6
Output data - (TD-)
Receiving data - (RD-)
4
,
5
,
7
,
8
unused
unused
Note: “+” and “-” represent the polarity of cable.
Definition for Direction Connection Cable from RJ45 (8-pin) to RJ45
(8-pin)
Fig.A-2 Order of Straight-through Cable
Definition for Cross Connection Cable from RJ45 (8-pin) to RJ45 (8-pin)
Fig.A-3 Order of Cross-over Cable
Summary of Contents for KIEN3016M
Page 1: ...KIEN3016M 3024M Industrial Ethernet Switch User s Manual KYLAND Telecom Technology Co Ltd...
Page 6: ......
Page 10: ......
Page 14: ......
Page 24: ...KIEN3016M 3024M Industrial Ethernet Switch User s Manual 14 Figure 3 7 b 2nd step...
Page 30: ......
Page 42: ......
Page 72: ......
Page 75: ...65...
Page 76: ......
Page 79: ......
Page 80: ......