-25-
Chapter Six
Testing Method
6.1
Self-Check
When the power is connected, all service indicators(except for POWER OUT) on the
front panel will flash one time, which means normal running of these ports. Later on,
the RUN indicator is on and DPX is always on..
6.2
Testing Ethernet Ports
Power KIEN3016M/3024M as shown in Fig. 6-1, make any two Ethernet interfaces
connect with the network port of the two testing computers by straight-through
network cable, transmit Ping command mutually, both sides can correctly Ping to each
other and no data package is lost. At the same time, the yellow lamp on the
corresponding port should keep on (computer network interface card operates in 100M
state), or keep off (computer network card operates in 10M state), and the green lamp
on the corresponding port should flash. This indicates the tested hardware of the two
electrical operates normally. The same testing method will be used to test all the rest
Ethernet interfaces (For detailed operation of the Ping command, please refer to the
following examples).
测试计算机1
测试计算机2
AR
1
2
3
5
7
4
6
8
11
9
13
12
10
14
15
AT
16
BT
BR
CT
CR
DT
DR
CONSOLE
DC POWER
AC220V
POWER
OFF
ON
KI EN3016M或KI EN3024M工业以太网交换机
Figure 6-1 Testing Ethernet port
KIEN3016M or KIEN3024M Industrial Ethernet Switch
Testing Computer 1
Testing Computer 2
Summary of Contents for KIEN3016M
Page 1: ...KIEN3016M 3024M Industrial Ethernet Switch User s Manual KYLAND Telecom Technology Co Ltd...
Page 6: ......
Page 10: ......
Page 14: ......
Page 24: ...KIEN3016M 3024M Industrial Ethernet Switch User s Manual 14 Figure 3 7 b 2nd step...
Page 30: ......
Page 42: ......
Page 72: ......
Page 75: ...65...
Page 76: ......
Page 79: ......
Page 80: ......