28 Chapter 06 – Measuring range
10911 V01.10
Relay 4 works with “committed switches” and reacts to the option bit. The option bit must be set to connect the route
to output 2. This corresponds to DiSEqC1.0 positions P3 or P4.
Multiswitch 6 switches 8 SAT IF levels. The selected path can be reached via P2V/Hi. However, as relay 4 requires the
option bit to be set, the “committed switches” setting must be P4V/Hi.
Settings must thus be made in all 4 DiSEqC1.1 submenus for the marked SAT IF route:
•
Set SAT-IF level to V/Hi
•
Set satellite position to P4
•
Set ”uncommitted switches“ to ”2 hex“
•
Set repetitions to 2
Afterwards, the display should show “P42V/Hi”. This setting connects the SAT IF route marked bold in the example. All
settings are incorporated in the tuning memory and can conveniently be recalled at a later date.
6.5.2.3 DiSEqC V1.2 control
Enter
LNB
> DiSEqC > V1.2 to open the DiSEqC V1.2 menu. V1.2 can be used to control positioners with DiSEqC rotors.
The menu includes the selection of the 4 LNB levels (identical to V1.0) and the control of a DiSEqC positioner.
The display of the position after “P” in the LNB window does not refer to the position of the position bit as in DiSEqC1.0.
Instead, it corresponds to the position number most recently called from the position memory of the DiSEqC rotor. If
you switch to DiSEqC V1.1 position number 1 of the DiSEqC rotor is moved to first.
Open the corresponding menu using
LNB
> Positioner.
Drive:
This allows the positioner to be moved to the east and west.
The cursor is at STOP when the menu is open. You can move the cursor to the “East” or “West” menu item using the
arrow keys. The motor then moves immediately to the east or west. You do not have to press
ENTER
first. The posi-
tioner stops immediately when the
STOP
menu item is activated.
Limit east:
This allows you to set an eastern limit that the positioner cannot pass. To do so, proceed as follows: First use the “Drive”
function to move the positioner to the position to be set as the eastern limit.
Then open the “Limit east” function. The limit is saved in the positioner when you press
ENTER
to confirm.
Limit west:
This allows you to set a western limit that the positioner cannot pass. To do so, proceed as follows: First use the “Drive”
function to move the positioner to the position to be set as the western limit. Then open the “Limit west” function. The
limit is saved in the positioner when you press
ENTER
to confirm.
Limits off:
This function allows you to cancel the east and west limits of the positioner. The motor can then travel back and forth
between its mechanical limits.
Save:
This function allows you to save a position reached using the “Drive” function in one of the position memory spaces
0—99. Position 0 is reserved for the reference position of 0 degrees. When called up, some positioners are subject to a
special function (e.g. Enable limits).