- 28 -
Checking Time
Checking Items
Startup
Check
50th
hour
Every 100
hours
Every 200
hours
Every 400
hours
Every
1,000
hours
Every
2,000
hours
13 Change Air Element
14 Adjust Tension V-Belt
1st time
2nd time
and after
15 Change V-Belt
or
2 years
16 Clean Radiator Fin
17 Clean Radiator (inside)
18
Change Fuel Hose,
Oil Hose,
Vibration-Absorbing
Rubber
or
2 years
19
Adjust Engine Valve
Clearance
Adjust-
ment
Lapping
20
Check/Adjust Injection
Nozzle
21
Check/Adjust Injection
Pump
(1) Oil Change
1) Remove the oil plug.
2) Loosen the oil drain plug and allow
the oil to drain fully.
3) Reinstall the oil drain plug.
4) Checking the oil level by the oil level
gauge, add oil into the oil filler to fill
up to the max level. (about 5.0 liter)
5) Reinstall the oil plug hand tight.
<Note>
•
Refer to "6-1 Checking Engine Oil" to select engine oil.
•
Change the packing, whenever changing oil.
•
Packing No. : 6C090-58961 (Kubota)
1st time
50th hour
2nd time
and after
Every 100 hours