About a Typical Pneumatic Circuit
4-13
990-HQ Service Manual
Typical Pneumatic Assembly
Pneumatic assembly setups vary in KVAL machines depending on where it is used and air
requirements.
This is a general overview of a pneumatic assembly
.
See the machine’s Air
Print for detailed information.
Air Input
Cylinder
Retract
Cylinder
Extend
Electrical Wiring Box: Con-
tains inputs from PLC to
Coils (Solenoids)
Manifold: Base to accept air input
and output air.
Coil (Solenoid): Receives input(24V)
from PLC to open a port
FIGURE4- 8.
Typical Pneumatic Assembly
About the Coil (Solenoid)
The Solenoids are connected to the top of the manifold. Labels indicating their function and PLC
connections are attached to the solenoid body. Use this information to troubleshoot system if nec-
essary.
Solenoid type will vary with machine application.
Common controls include an operational LED and
Manual operation button
Manual Activate Button: Push to toggle solenoid to the
‘ON’ state. activates if power is off.
Indicator: a Lit LED indicates the solenoid is in use.Red
LED= the ‘A’ Port on a single valve. If double valve,
Red LED= the ‘A’ Port and Green LED = the ‘B’ port.
FIGURE4- 9.
Solenoids in Manifold
Summary of Contents for 990-HQ
Page 4: ...KVAL 990 HQ Service Manual ...
Page 9: ...Notes ...
Page 29: ...Safety Sign Off Sheet 1 20 990 HQ Service Manual ...
Page 38: ...Network System Overview 2 9 990 HQ Service Manual ...
Page 65: ...Lubrication Points on the 990 HQ 3 27 990 HQ Service Manual FIGURE 3 18 Bearings Back Section ...
Page 79: ...Collet Torque Values 3 41 990 HQ Service Manual ...
Page 80: ...Appendix Conversion Chart 3 42 990 HQ Service Manual Appendix Conversion Chart ...
Page 81: ...Appendix Conversion Chart 3 43 990 HQ Service Manual ...
Page 108: ...Troubleshooting with the Status Light Panel 4 27 990 HQ Service Manual ...
Page 111: ......