Troubleshooting Basics
4-5
990-HQ Service Manual
Before you Adjust
Determine What:
What Subsystem is Respon-
sible for the Failed Sequence
Step.
Analyze the subsystem:
Check the
Load
.
Check the Position Feed Back.
Check the Positioning System
See “Analyze the Sub Systems” on
TABLE 4-1.
Typical KVAL Machine Sequence
Typical Machine
Sequence
Responsible Sub-
system
1. Move Door into Posi-
tion
Feed System
2. Clamp the Door
Door Clamp
3. Make the Cuts
Cutter Position-
ing Cutter Power
4. Unclamp the Door
Door Clamp
5. Move Door Out
Feed System
Basic Troubleshooting Steps
Determine Where:
The Sequence Step Where
the Failure Occurs
What was the Machine Trying to Do?
What Was the Machine Trying to Do Next?
Check the Sequences in the Table Below.
How is the Broken Section Suppose to Work?
What is Keeping the Broken Section From
Working?
What Part of the Machine is not Working?
Check the Subsystems in the Table Below.
Ask
Narrow
Verify
Analyze the Sub Systems
1.
Check the
Load
for mechanical issues
• Is the Load “bound up?
• Is there sufficient lubrication?
• Is it an alignment issue?
• Is anything damaged?
2.
Check the
Position Feed Back
.
Summary of Contents for 990-HQ
Page 4: ...KVAL 990 HQ Service Manual ...
Page 9: ...Notes ...
Page 29: ...Safety Sign Off Sheet 1 20 990 HQ Service Manual ...
Page 38: ...Network System Overview 2 9 990 HQ Service Manual ...
Page 65: ...Lubrication Points on the 990 HQ 3 27 990 HQ Service Manual FIGURE 3 18 Bearings Back Section ...
Page 79: ...Collet Torque Values 3 41 990 HQ Service Manual ...
Page 80: ...Appendix Conversion Chart 3 42 990 HQ Service Manual Appendix Conversion Chart ...
Page 81: ...Appendix Conversion Chart 3 43 990 HQ Service Manual ...
Page 108: ...Troubleshooting with the Status Light Panel 4 27 990 HQ Service Manual ...
Page 111: ......