Contactor
Thermal Over-
load
About a Typical Contactor Control
4-8
990-HQ Service Manual
FIGURE4- 3.
Contactor Bank
About Contactor Troubleshooting
The Thermal Overload Circuit opens the motor circuit when current draw causes the motor to run
too hot. The overload limits are set at the factory, do not adjust the limits.
The overloads are normally in series, therefore if one trips, all on that circuit stop working.
Use the Six Light panel as a trigger to check the circuit.
See “Troubleshooting with the Status
1.
Open the Main Electrical Cabinet to find the Contactor /Thermal Overload Assem-
bly
2.
Press each ‘Green” Reset button on the Thermal Overload. An audible click will be
heard on the tripped circuit. (Take note of tripped circuit.)
3.
Once the overloads are reset, verify LED’s are on.
4.
Rerun the machine and verify that motor runs without tripping the circuit.
5.
If the same overload keeps tripping, verify condition.
6.
Follow circuit path using the E-Drawing as a reference.
a.Common issues: Check for bad wire, bad motor, or if load is too great for cur-
rent draw.
Summary of Contents for 990-HQ
Page 4: ...KVAL 990 HQ Service Manual ...
Page 9: ...Notes ...
Page 29: ...Safety Sign Off Sheet 1 20 990 HQ Service Manual ...
Page 38: ...Network System Overview 2 9 990 HQ Service Manual ...
Page 65: ...Lubrication Points on the 990 HQ 3 27 990 HQ Service Manual FIGURE 3 18 Bearings Back Section ...
Page 79: ...Collet Torque Values 3 41 990 HQ Service Manual ...
Page 80: ...Appendix Conversion Chart 3 42 990 HQ Service Manual Appendix Conversion Chart ...
Page 81: ...Appendix Conversion Chart 3 43 990 HQ Service Manual ...
Page 108: ...Troubleshooting with the Status Light Panel 4 27 990 HQ Service Manual ...
Page 111: ......