Service and maintenance
9
94
9.5
Checking the position of the spreading disc hub
The spreading disc hub must be centred exactly under the agitator.
Figure 9.7:
Checking the position of the spreading disc hub
Requirements:
The spreading discs have been removed.
Testing the centring:
1.
Use suitable equipment to check that the spreading disc hub and agitator are
centred (e.g. straight edge ruler, protractor)
The axes of the spreading disc hub and the agitator must be aligned. The
maximum allowable deviation is
2 mm
.
If this margin is exceeded, please contact your dealer or authorised service cen-
tre.
Checking distance:
2.
Measure the gap between upper edge of spreading disc hub and the lower
edge of the agitator.
The distance must be
136.5 mm
(permissible tolerance ± 2 mm).
If this margin is exceeded, please contact your dealer or authorised service cen-
tre.
136,5
_
+ 2 mm
< 2 mm
Summary of Contents for AXIS H 30.1 EMC
Page 2: ......
Page 4: ......
Page 10: ...Intended use 1 2 ...
Page 36: ...Technical data 4 28 ...
Page 40: ...Axle load calculation 5 32 ...