Spreading operation
83
8
Spreader feeds more on one side
Container empties unevenly dur-
ing normal spreading.
fertiliser bridging above the agitator
Remove fertiliser to the height of the safety screen on the
affected side.
Break up accumulated fertiliser with a wooden stick
through the bars of the safety screen.
Outlet blocked
See metering outlet blockages.
Defective agitator
Remove fertiliser to the height of the safety screen on the
affected side.
Open the metering outlet and break up accumulated fer-
tiliser with a wooden stick through the bars of the safety
screen so that the remaining fertiliser can run out of the
outlet opening.
Check functionality of agitator drive. see chapter
9.6: Checking agitator drive, page 95
.
Metering slide set incorrectly
Empty the container of remaining fertiliser. see chapter
8.11: Discharging residue, page 85
Check metering slide setting. see chapter
.
Irregular fertiliser feed to spread-
ing disc
Fertiliser bridging above the agitator
Remove fertiliser to the height of the safety screen on the
affected side.
Break up accumulated fertiliser with a wooden stick
through the bars of the safety screen.
Outlet blocked
See metering outlet blockages.
Defective agitator
Remove fertiliser till the height of the safety screen on the
affected side.
Open the metering outlet and break up accumulated fer-
tiliser with a wooden stick through the bars of the safety
screen so that the remaining fertiliser can run out of the
outlet opening.
Check functionality of agitator drive. see chapter
9.6: Checking agitator drive, page 95
.
Spreading discs flutter
Check that cap nuts are tight and the thread sits properly.
Metering slide opens with difficulty
or not at all.
Metering slides do not move easily. Regularly check
slides, nuts and screws for tight fit and tighten them, if
necessary.
Fault
Possible cause/action
Summary of Contents for AXIS H 30.1 EMC