![KUHL AXIS H 30.1 EMC Operator'S Manual Download Page 109](http://html.mh-extra.com/html/kuhl/axis-h-30-1-emc/axis-h-30-1-emc_operators-manual_2009382109.webp)
Service and maintenance
101
9
9.9
Metering slide adjustment
Check that the metering slides open evenly before every working season and
also during the season, if necessary.
Requirements:
The mechanics must be freely movable to check the metering slide setting.
Actuator is disengaged.
Running the test (example on left side of spreader):
2.
Push the metering slide against the pin.
The pointer must point to 85 on the metering slide scale. If position is
not correct, the scale must be adjusted.
n
WARNING
Danger of crushing and shearing!
Power-operated components (adjusting lever, metering slide)
may crush and shear when working on them.
Pay attention to the shear points of the metering outlet and
slides during all adjustment work.
Turn off tractor. Remove the ignition key.
Do not operate hydraulic slide actuators during adjust-
ment work.
1.
Take a lower link pin
d = 28
mm
and insert it centrally
into the outlet.
Figure 9.13:
Lower link pin in metering out-
let
Summary of Contents for AXIS H 30.1 EMC
Page 2: ......
Page 4: ......
Page 10: ...Intended use 1 2 ...
Page 36: ...Technical data 4 28 ...
Page 40: ...Axle load calculation 5 32 ...