25
KSi SC PRO APPLICATOR
USER'S MANUAL
Cleaning Procedure Overview
1. Remove all left-over treatment slurry from tanks into appropriate storage containers by operating
pumps.
2. Add water and mild detergent to the tanks. Start agitator and allow run for up to several hours.
3. Turn 3-way calibration valve to calibrate, start pump to flush the calibration tube and lines.
Disassemble and clean calibration tube and squeegee.
4. Disconnect treatment line to the applicator chemical manifold, place end of line into the tank. Turn
3-way calibration valve to treat, start pump to flush the lines. If a Micromatic Keg Coupler is used,
place coupler into a container of water and mild detergent for pump to flush the lines into a catch
container. (Note: You will have to slightly press in center green seal on Micromatic to allow it to intake
cleaning water)
5. Reconnect treatment lines to applicator head, and remove Atomizer discharge spout and place a 5
gal bucket around atomizer disk area discharge to collect waste.
6. Run pump to pump cleaning solution through the applicator head and allow it to drain into the 5 gal
bucket.
7. After cleaning water is pumped through, turn off pump, remove 5 gal bucket, dispose of waste.
8. Atomizer disk is plastic, handle with care, with a medium bristle brush, scrub the atomizer disc,
inside of the applicator head, and transition.
9. DO NOT PRESSURE WASH INSIDE THE TREATER HEAD. PRESSURE WASHING THIS AREA
WILL RESULT IN THE ATOMIZER MOTOR SIEZING UP AND REQUIRING REPLACEMENT OF
THE ATOMIZER MOTOR.
10. Allow everything to dry and then re-assemble. Use a Shop Vac to clean out Conveyor lower
cleanout access area of seed.
11. If chemical pumps are stored in an UNHEATED environment during the off season, RV Antifreeze
or windshield wiper fluid should be pumped through the system to avoid freezing. Or leave all low
point Push to connects disconnected to drip dry and make sure no liquid is left in any part of system.
SIMPLE GREEN AND WATER IS THE RECOMMENDED CLEANING
SOLUTION
DISPOSE OF ALL WASTE ACCORDING TO LOCAL REGULATIONS
**THIS PROCEDURE IS A GOOD PRACTICE FOR WINTERZATION AND TO
HELP REDUCE EARLY SEASON MAINTENANCE BREAKDOWNS
Summary of Contents for SC Pro
Page 1: ...SC Pro Applicator Owner Operator s Manual...
Page 15: ...11 KSi SC PRO APPLICATOR USER S MANUAL KS 0017 KS 0015...
Page 16: ...12 KSi SC PRO APPLICATOR USER S MANUAL KS 0010 KS 0029...
Page 17: ...13 KSi SC PRO APPLICATOR USER S MANUAL KS 0030 KS 0016...
Page 18: ...14 KSi SC PRO APPLICATOR USER S MANUAL KS 0008...
Page 34: ...30 KSi SC PRO APPLICATOR USER S MANUAL 25405 06...
Page 36: ...32 KSi SC PRO APPLICATOR USER S MANUAL 25344 10...
Page 38: ...34 KSi SC PRO APPLICATOR USER S MANUAL 121216 51 SC02 SMX Conveyor...
Page 41: ...37 KSi SC PRO APPLICATOR USER S MANUAL Thispageleftblankintentionally...
Page 42: ...38 KSi SC PRO APPLICATOR USER S MANUAL 161019 51 SC03 SMX Conveyor...
Page 45: ...41 KSi SC PRO APPLICATOR USER S MANUAL Thispageleftblankintentionally...
Page 46: ...42 KSi SC PRO APPLICATOR USER S MANUAL 10 General Dimensions Specs Section 10...