5 Installation at Site
29 of 74
HPK-L
1136.8/15-EN
CAUTION
Misalignment of pump and motor shafts
Damage to pump, motor and coupling!
▷
Always check the coupling after the pump has been installed and connected to
the piping.
▷
Also check the coupling of pump sets supplied with pump and motor mounted
on the same baseplate.
B
A
A
B
1
1
2
Fig. 14:
Non-spacer-type coupling, checking the coupling alignment
1
Straight edge
2
Gauge
B
B
A
A
2
1
1
Fig. 15:
Spacer-type coupling, checking the coupling alignment
1
Straight edge
2
Gauge