5 Installation at Site
27 of 74
HPK-L
1136.8/15-EN
Sizes
Suction nozzle
Discharge nozzle
Suction nozzle
Discharge nozzle
[N]
[N]
[Nm]
[Nm]
F
x
F
y
F
z
F
res
F
x
F
yTens
+ F
yCompr
-
F
z
F
res
M
x
M
y
M
z
M
x
M
y
M
z
80-315
3700
2400
2950
3800
1700
1100
2150
1400
2200
2750 2100 1400 1450 1100
750
80-400
3700
2400
2950
3800
1700
1100
2150
1400
2200
2750 2100 1400 1450 1100
750
100-200
3700
2400
2950
3800
2150
1350
2700
1750
2800
2750 2100 1400 2000 1500 1000
100-250
3700
2400
2950
3800
2150
1350
2700
1750
2800
2750 2100 1400 2000 1500 1000
100-315
3700
2400
2950
3800
2150
1350
2700
1750
2800
2750 2100 1400 2000 1500 1000
100-400
3700
2400
2950
3800
2150
1350
2700
1750
2800
2750 2100 1400 2000 1500 1000
125-250
4700
3100
3750
4750
2950
1850
3700
2400
3800
3450 2650 1750 2750 2100 1400
125-315
4700
3100
3750
4750
2950
1850
3700
2400
3800
3450 2650 1750 2750 2100 1400
125-400
4700
3100
3750
4750
2950
1850
3700
2400
3800
3450 2650 1750 2750 2100 1400
150-250
7350
4700
5700
7400
3750
2350
4700
3100
4850
5300 3850 2650 3450 2650 1750
150-315
7350
4700
5700
7400
3750
2350
4700
3100
4850
5300 3850 2650 3450 2650 1750
150-400
7350
4700
5700
7400
3750
2350
4700
3100
4850
5300 3850 2650 3450 2650 1750
150-500
7350
4700
5700
7400
3750
2350
4700
3100
4850
5300 3850 2650 3450 2650 1750
200-250
7350
4700
5700
7400
5700
3550
7350
4700
7400
5300 3850 2650 5300 3850 2650
200-315
10000 6700
8000 10450 5700
3550
7350
4700
7400
7500 5700 3650 5300 3850 2650
200-400
10000 6700
8000 10450 5700
3550
7350
4700
7400
7500 5700 3650 5300 3850 2650
200-500
10000 6700
8000 10450 5700
3550
7350
4700
7400
7500 5700 3650 5300 3850 2650
250-315
12000 8000 10000 12800 8000
5000 10000 6700 10450 9150 6900 4500 7500 5700 3650
250-400
12000 8000 10000 12800 8000
5000 10000 6700 10450 9150 6900 4500 7500 5700 3650
250-500
12000 8000 10000 12800 8000
5000 10000 6700 10450 9150 6900 4500 7500 5700 3650
Correction coefficients depending on material and temperature (see diagram below).
1,00
0,75
0,80
0,85
0,90
0,95
0,50
0,55
0,60
0,65
0,70
400
350
300
250
200
150
120
JL1040
N
JS1025
1.4408
°C
Correction coefficient
Fig. 12:
Temperature correction diagram
No reduction is necessary for material 1.7706.
5.3.3 Auxiliary connections
DANGER
Risk of potentially explosive atmosphere by incompatible fluids mixing in the
auxiliary piping
Risk of burns!
Explosion hazard!
▷
Make sure that the barrier fluid or quench liquid are compatible with the fluid
handled.
The pump is fully functional without any external cooling system. Standard pump
sets with one mechanical seal do not require any cooling liquid, barrier fluid or
flushing liquid.