8 Trouble-shooting
69 of 78
Etanorm-R
1222.8/13-EN
A B C D E
F G H Possible cause
Remedy
25)
-
✘
-
-
-
-
✘
- Pump back pressure is lower than
specified in the purchase order.
Re-adjust to duty point.
In the case of persistent overloading, turn
down impeller.
26)
-
✘
-
-
-
-
-
- Density or viscosity of fluid handled
higher than stated in purchase order
Contact KSB.
-
-
-
-
-
✘
-
- Use of unsuitable shaft seal materials
Change the material combination.
26)
-
✘
-
-
-
✘
-
- Gland follower over-tightened or cocked Correct.
-
✘ ✘
-
-
-
-
- Speed is too high.
Reduce speed.
26)
-
-
-
-
✘
-
-
- Tie bolts/sealing element defective
Fit new sealing element between volute
casing and discharge cover.
Re-tighten the bolts.
-
-
-
-
-
✘
-
- Worn shaft seal
Fit new shaft seal.
Check flushing liquid/barrier fluid.
✘
-
-
-
-
✘
-
- Score marks or roughness on shaft
protecting sleeve / shaft sleeve
Replace shaft protecting sleeve/shaft sleeve.
Fit new shaft seal.
-
-
-
-
-
✘
-
- Dismantle to find out.
Correct.
Fit new shaft seal, if required.
-
-
-
-
-
✘
-
- Vibrations during pump operation
Correct the suction conditions.
Re-align the pump set.
Re-balance the impeller.
Increase pressure at the pump suction nozzle.
-
-
-
✘
-
✘ ✘
- Pump set is misaligned.
Re-align pump set.
-
-
-
✘
-
✘ ✘
- Pump is warped or sympathetic
vibrations in the piping.
Check the piping connections and secure
fixing of pump; if required, reduce distances
between the pipe clamps.
Fix the pipelines using anti-vibration material.
-
-
-
✘
-
-
-
- Increased axial thrust
26)
Clean balancing holes in the impeller.
Replace the casing wear rings.
-
-
-
✘
-
-
-
- Insufficient or excessive quantity of
lubricant or unsuitable lubricant.
Top up, reduce or change lubricant.
-
-
-
✘
-
-
-
- Non-compliance with specified coupling
distance
Correct the distance according to general
arrangement drawing.
✘ ✘
-
-
-
-
-
- Motor is running on two phases only.
Replace the defective fuse.
Check the electric cable connections.
-
-
-
-
-
-
✘
- Rotor out of balance
Clean the impeller.
Re-balance the impeller.
-
-
-
-
-
-
✘
- Defective bearing(s)
Replace.
-
-
-
✘
-
-
✘ ✘
Flow rate is too low.
Increase the minimum flow rate.
-
-
-
-
-
✘
-
- Incorrect inflow of circulation liquid
Increase the free cross-section.