7 Servicing/Maintenance
72 of 126
Amacan S
1589.837/01-EN
Table 23:
Symbols key
Symbol
Description
L
243
Always secure screwed connections marked with this symbol with
Loctite 243
.
ü
A new O-ring has been inserted into the groove of motor housing cover 812.
1. Attach lifting equipment to eyebolt 900.04 or bail 571 of motor housing cover
812. Lift up the motor housing cover and lower it down onto motor housing 811
or motor unit 80-1 until only a gap remains which allows work to continue.
Watch the alignment grooves in motor housing cover 812 and motor housing
811. The alignment grooves must be properly aligned.
2. Connect plug 81-2 of the control cable to the corresponding connector.
3. Connect the power cable cores to terminal board 835 with disc 550.23, circlip
932.23 and nuts 920.23/920.24 in accordance with the wiring diagram.
4. Tie the cores of the control cable and power cable together with cable ties.
5. Slowly lower motor housing cover 812 onto motor housing 811. Watch the
alignment grooves in motor housing cover 812 and motor housing 811. The
alignment grooves must be properly aligned.
6. Fasten motor housing cover 812 to motor housing 811 or motor unit 80-1 with
socket head cap screws 914.01. Secure with Loctite 243. Observe the tightening
torque! (
7. Cover the extraction threads with caps 903.51.
8. Perform a leak test on the motor. (
7.6.4 Installing the mechanical seal
Observe the following to ensure trouble-free operation of the mechanical seal:
▪
Only remove the protective wrapping of the contact faces immediately before
assembly takes place.
▪
The shaft surface must be absolutely clean and undamaged.
▪
Immediately before installing the mechanical seal, wet the contact faces with a
drop of oil.
▪
For easier installation of bellows-type mechanical seals, wet the inside diameter
of the bellows or the O-rings with soapy water (not oil).
▪
Cover any grooves in the shaft into which the O-rings could slide with suitable
means or assembly aids.
▪
To prevent any damage to the rubber bellows, place a thin foil (of approximately
0.1 to 0.3 mm thickness) around the free shaft stub.
Slide the rotating assembly over the foil into its installation position.
Then remove the foil.