5 Installation at Site
27 of 126
Amacan S
1589.837/01-EN
1
2
3
Fig. 8:
Installation position of the pump set
1
Bail
2
Anti-swirl baffles
3
Flow-straightening vane
5.3.2 Installing the pump set without support rope
CAUTION
Incorrect installation
Damage to the pump set!
▷
Verify that the pump set is correctly seated in the discharge tube.
412.05
101
Fig. 9:
Inserting the O-ring
Always refer to and comply with the general arrangement drawing/outline drawing
when installing the pump set.
1. If O-ring 412.05 is supplied but not fitted, insert it into pump casing 101.
2. Attach the crane hook the bail of the pump set.
3. Centre the pump set above the discharge tube. Slowly lower the pump set into
the discharge tube until it is seated in the recommended position.
(
4. Pull the cables up by hand. Fasten them to the sump construction with a cable
support sleeve, if required. Do not lift the pump set out of its seat.
X
X
Fig. 10:
Fastening the cable support sleeve
Summary of Contents for Amacan S 1000-600