5 Installation at Site
26 of 126
Amacan S
1589.837/01-EN
WARNING
Incorrect handling of the electric cable
Personal injury and damage to property!
▷
Secure electric cables against falling down.
▷
Avoid electric cables being laid on surfaces without fastening.
▷
When moving the pump set keep at a safe distance to the electric cables.
WARNING
People falling into the unsecured discharge tube
Risk of personal injury!
▷
Take suitable precautions during the entire installation/removal process to
protect people from falling into the open discharge tube.
▷
Fence off the work area appropriately.
5.3.1 Information for correct installation
The
flow-straightening vane
is
indispensable
for the inlet conditions of the pump
set. It prevents the development of a submerged vortex (floor vortex) which could
cause a drop in performance, for example. To provide optimum inlet conditions,
observe the following information:
1.
Observe the structural requirements!
Install the flow-straightening vane concentrically below the discharge tube, see
general arrangement drawing.
1
2
3
Fig. 7:
Installation position of the flow-straightening vane
1
Flow-straightening vane
2
Discharge tube
3
Intake chamber
2.
Observe the installation position of the pump set!
Lower the pump set into the discharge tube with the anti-swirl baffles (2) in the
bellmouth aligned with the flow-straightening vane (3).
Use the bail alignment of the pump set for orientation. The bail (1) is aligned
with the anti-swirl baffles (2).