7 Servicing/Maintenance
70 of 126
Amacan S
1589.837/01-EN
7.6.2 Installing the replacement cable gland
571
82-11
81-97.02*
834.01
412.07
914.04
81-97.01
914.25
834.02*
412.08*
914.05*
81-51*
350
L
243
L
243
Fig. 40:
Installing the power cable and cable gland
*: On specific designs only
Table 22:
Symbols key
Symbol
Description
L
243
Always secure screwed connections marked with this symbol with
Loctite 243
.
Installing the power cable,
version without plug
1. Adjust the lengths of the cable cores to the original cable gland.
2. Attach the core identification to match the original cable gland.
3. Slide O-ring 412.07 onto the core ends of the power cable and into the groove
of the centring seat.
4. Use a connector to connect the strands of motor and cable gland.
5. Pull a heat shrink tube over the connection point.