5 Installation at Site
31 of 126
Amacan S
1589.837/01-EN
5.3.4 Installing the pump set with a support rope and support spacer
Always refer to and comply with the general arrangement drawing/outline drawing
when installing the pump set.
Prior to installing the pump set, visually inspect the support rope. Do not exceed the
permissible load-carrying capacity.
X
59-24
X
59-17.01
Fig. 17:
X = indication of load-carrying capacity
59-24
Support rope
59-17.01
Shackle
CAUTION
Incorrect installation
Damage to the pump set!
▷
Verify that the pump set is correctly seated in the discharge tube.
WARNING
Pump set drops during the installation or removal process
Personal injury and damage to property!
▷
Never use the turnbuckle , shackle or discharge tube cover to lift the pump set.
▷
Always use lifting lug 59-47.
NOTE
Prior to fitting the turnbuckle, check that the corresponding split pin has not been
cracked or chipped. If damaged, always use a new split pin.
ü
Suitably sized lifting equipment is available.
ü
The support has been supplied pre-assembled and is available for use.
ü
The support rope has been visually inspected.
ü
The split pin of the turnbuckle has been checked for any damage.
412.05
101
Fig. 18:
Inserting the O-ring
1. If O-ring 412.05 is supplied but not fitted, insert it into pump casing 101.
Summary of Contents for Amacan S 1000-600
Page 125: ......