Motor sizes
Pump set
DKN 92
F 50-220
S50-22...
F65-170
F 80-220
D 80-220
F 100-220
D 100-220
3
1
2
Shaft
Pump casing
Cable gland
Flamepath number
1
2
3
Length of flamepath [mm]
≥ 12.5
≥ 12.5
≥ 12.5
Inside diameter (drilled hole) [mm]
30
≥ 152
32
Outside diameter (shaft) [mm]
29.9
152
32
Tolerance ISO inside diameter
F7
H8
H8
Tolerance ISO outside diameter
-
g6
-
Tolerance in µm inside diameter to
DIN ISO 286/2
Maximum
+41
+63
+39
Minimum
+20
0
0
Tolerance in µm outside diameter to
DIN ISO 286/2
Maximum
-
-14
-
Minimum
-
-39
-
Tolerance in µm inside diameter
Maximum
-
-
-
Minimum
-
-
-
Tolerance in µm outside diameter
Maximum
-40
-
-25
Minimum
-60
-
-75