3
Transport/Temporary Storage/Disposal
3.1
Transport
DANGER
Improper transport
Danger to life from falling parts!
Damage to the pump set!
▷
Use the attachment point (pump handle) provided for attaching lifting tackle.
▷
Never suspend the pump set by its power cable.
▷
Never use the chains or lifting ropes included in KSB's scope of supply for lifting
loads other than the KSB product supplied.
▷
Safely attach transport ropes or chains to the pump and crane.
▷
The number on the sign attached to the pump set must match the number on
the sign attached to the chain.
Transport the pump set as illustrated.
Fig. 1: Transporting the pump set
3.2
Storage and preservation
If commissioning is to take place some time after delivery, we recommend that the
following measures be taken for pump storage:
CAUTION
Improper storage
Damage to the power cables!
▷
Support the power cables at the cable entry to prevent permanent deformation.
▷
Only remove the protective caps from the power cables at the time of
installation.
CAUTION
Damage during storage by humidity, dirt, or vermin
Corrosion/contamination of the pump (set)!
▷
For outdoor storage cover the pump (set) or the packaged pump (set) and
accessories with waterproof material.
CAUTION
Wet, contaminated or damaged openings and connections
Leakage or damage to the pump set!
▷
Only remove caps/covers from the openings of the pump set at the time of
installation.
3 Transport/Temporary Storage/Disposal
12 of 66
Amarex® N
Goodnal STP ST041 Biological Treatment (KSB WAS PUMP 1 & 2 PU-0530-010 OM Instructions) Vendor Manual
Q-Pulse Id VM381
Active 29/10/2013
Page 14 of 76