7.3
Drainage/disposal
WARNING
Fluids posing a health hazard
Hazardous to persons and the environment!
▷
Collect and properly dispose of flushing liquid and any fluid residues.
▷
Wear safety clothing and a protective mask, if required.
▷
Observe all legal regulations on the disposal of fluids posing a health hazard.
1. Always flush the pump if it has been used for handling noxious, explosive, hot or
other hazardous fluids.
2. Always flush and clean the pump before sending it to the workshop.
Make sure to add a certificate of decontamination. (
7.4
Dismantling the pump set
7.4.1 General information/Safety regulations
WARNING
Unqualified personnel performing work on the pump (set)
Risk of personal injury!
▷
Always have repair and maintenance work performed by specially trained,
qualified personnel.
WARNING
Hot surface
Risk of personal injury!
▷
Allow the pump set to cool down to ambient temperature.
Observe the general safety instructions and information.
For dismantling and reassembly observe the general assembly drawing.
In case of damage you can always contact our service staff.
DANGER
Insufficient preparation of work on the pump (set)
Risk of personal injury!
▷
Properly shut down the pump set.
▷
Close the shut-off elements in the suction and discharge line.
▷
Drain the pump and release the pump pressure.
▷
Close any auxiliary connections.
▷
Allow the pump set to cool down to ambient temperature.
7.4.2 Preparing the pump set
✓
The notes and steps stated in (
Section 7.4.1 Page 42) have been observed/
carried out.
1. Completely disconnect the pump set from the power supply.
2. Drain the lubricant.
3. Drain the leakage chamber and leave it open during dismantling.