Table 8: Anchor bolt dimensions
Size
d
o
[mm]
t=h
requ
[mm]
t
fix
[mm]
SW
[mm]
M
[mm]
Hex.
head
WAF
[mm]
Torque
instal
[Nm]
M 10x130
12
90
20
17
10
7
20
M 16x190
18
125
35
24
16
12
60
Table 9: Curing times of mortar cartridge
Floor temperature
Curing time
[min]
-5 °C to 0 °C
240
0 °C to +10 °C
45
+10 °C to +20 °C
20
> +20 °C
10
5.3.1.2 Connecting the piping
DANGER
The permissible loads on the flange of the duckfoot bend have been exceeded
Danger to life from leakage of hot, toxic, corrosive or flammable fluids!
▷
Do not use the pump as an anchorage point for the piping.
▷
Anchor the pipelines in close proximity to the pump and connect them without
transmitting any stresses or strains.
▷
Observe the permissible flange loads.
▷
Take appropriate measures to compensate thermal expansion of the piping.
NOTE
When the pump set is used for draining low-level building areas, install a swing check
valve in the discharge line to avoid backwash from the sewer system.
CAUTION
Critical speed
Increased vibrations!
Damage to mechanical seals and bearings!
▷
Install a swing check valve in longer riser pipes to prevent the pump from
excessive running in reverse.
When fitting a swing check valve, make sure that the unit can still be vented
properly.
Table 10: Permissible flange loads
Nominal flange
diameter
Forces [N]
Moments [Nm]
F
y
F
z
F
x
∑
F
M
y
M
z
M
x
∑
M
50-65
1350
1650
1500
2600
1000
1150
1400
2050
80
2050
2500
2250
3950
1150
1300
1600
2350
100
2700
3350
3000
5250
1250
1450 1750
2600
t
=
h
req
t
fix
WAF
M
Hex. Head WAF
do
l
Fig. 6: Dimensions
F
x
F
z
F
y
M
y
M
z
M
x
Fig. 7: Permissible flange
loads