Installation at Site
5.1
Safety regulations
DANGER
Improper installation in potentially explosive atmospheres
Explosion hazard!
Damage to the pump set!
▷
Comply with the applicable local explosion protection regulations.
▷
Observe the information given in the data sheet and on the name plate of the
pump set.
DANGER
Persons in the tank during pump operation
Electric shock!
▷
Never start up the pump set when there are persons in the tank.
5.2
Checking the site before installation
5.2.1 Preparing the place of installation
Place of installation for stationary models
WARNING
Installation on foundations which are unsecured and cannot support the load
Personal injury and damage to property!
▷
Make sure the foundation concrete is of sufficient strength (min. class 32.5 N to
EN 197-1 or equivalent).
▷
Make sure the foundation has set firmly before placing the duckfoot bend on it.
▷
Only place the duckfoot bend on horizontal and level surfaces.
▷
Refer to the weights given in the data sheet/on the name plate.
Any resonances at the usual excitation frequencies (1 x and 2 x rotational frequency,
rotational noise) must be prevented both in the foundation and in the connected
piping, as such frequencies may cause extreme vibrations.
1. Check the structural requirements.
All structural work required must have been prepared in accordance with the
dimensions stated in the outline drawing/general arrangement drawing.
Place of installation for transportable models
WARNING
Placing the pump set on an unsecured and uneven mounting surface
Personal injury and damage to property!
▷
Always place the pump set on a solid and level surface with the pump set in
vertical position and the motor on top.
▷
Only place the pump set on a surface of sufficient load-carrying capacity.
▷
Use appropriate means to secure the pump set against overturning or tipping
over.
▷
Refer to the weights given in the data sheet/name plate.
Any resonances at the usual excitation frequencies (1 x and 2 x rotational frequency,
rotational noise) must be prevented both in the foundation and in the connected
piping, as such frequencies may cause extreme vibrations.
Resonances
Resonances
5 Installation at Site
18 of 66