1. Check the structural requirements.
All structural work required must have been prepared in accordance with the
dimensions stated in the outline drawing/general arrangement drawing.
5.2.2 Checking the lubricant level
The lubricant reservoirs are filled with an environmentally-friendly, non-toxic
lubricant at the factory.
1. Position the pump set as shown.
2563:108
2563:109
a)
b)
Fig. 3: Checking the lubricant level a) Variants YL and WL; B) Variants YL and WL for
pump sizes 50-17... and 65-220
2. Unscrew screwed plug 903 with joint ring 411.
⇨
The lubricant level must be 21 mm below the filler opening (50 mm for pump
sizes 50-17... and 65-220 YL and WL).
3. If the lubricant level is any lower, top up the lubricant reservoir through the filler
opening until the indicated level is reached. .
4. Close screwed plug 903 with joint ring 411. Observe the tightening torques. (
5.2.3 Checking the direction of rotation
DANGER
Pump set running dry
Explosion hazard!
▷
The direction of rotation of explosion-proof pump sets must be checked outside
the potentially explosive atmosphere.
WARNING
Hands or objects inside the pump casing
Risk of injuries, damage to the pump!
▷
Never insert your hands or any other objects into the pump.
▷
Check that the inside of the pump is free from any foreign objects.
CAUTION
Pump set running dry
Increased vibrations!
Damage to mechanical seals and bearings!
▷
Never operate the pump set for more than 60 seconds outside the fluid to be
handled.
✓
The pump set is connected to the power supply.
1. Start the pump set and stop it again immediately to determine the motor's
direction of rotation.