Settings
102
Pos: 40.18.1 /Überschriften/Überschriften 2/P-T/S/Sensor kalibrieren - bei Ausführung elektrische Kreiselhöhenverstellung @ 359\mod_1439199697912_78.docx @ 2661656 @ 2 @ 1
11.6
Calibrating the Sensor – with Electrical Rotor Height Adjustment Design
Pos: 40.18.2 /BA/Einstellungen/Schwader/Sensor kalibrieren - Einleitung @ 359\mod_1439198670211_78.docx @ 2662277 @ @ 1
The calibration only works if sensor voltage is less than 1 V (bottom stop) or greater than 4 V
(upper stop).
If this is not the case, consult KRONE specialist workshop so that the sensor can be readjusted
mechanically until the voltage values are again in the permissible range.
•
Park machine on level and firm ground so that both rotors are parallel to the ground.
•
Set the rotors to the least working height. In doing so, make sure that both rotors have the
same distance to the ground.
Due to allowed deviating tolerances of parts, the displays may contain different values before
calibration is performed.
Pos: 40.18.3 /BA/Einstellungen/Schwader/Sensor kalibrieren - Bild_TS-Maschinen @ 359\mod_1439200552195_78.docx @ 2662337 @ @ 1
2
1
TS620-007
Fig. 61
Pos: 40.18.4 /BA/Einstellungen/SchwaderSensor kalibrieren - Anzeigen nullen und Kalibriervorgang @ 391\mod_1445846105479_78.doc x @ 2799563 @ @ 1
Resetting the displays to zero
•
Lay permanent magnet on the display.
Calibration was successful
when the display flashes three times
.
If the display does not flash
, perform calibration again.
Calibration process
•
Move each of the both rotors down to the ground.
•
Hold permanent magnet over the right display (1).
The right display flashes for approx. 5 seconds.
After that measurement value 0 is saved as lower limit of measuring range.
• Remove
magnet.
•
Hold permanent magnet over the left display (2).
The left display flashes for approx. 5 seconds.
After that measurement value 0 is saved as lower limit of measuring range.
• Remove
magnet.
•
Raise both rotors to headland position and raise rotor height adjustment until the stop is
reached.
•
Hold permanent magnet over the right display (1).
The right display flashes for approx. 5 seconds.
After that measurement value 99 is saved as upper limit of measuring range.
• Remove
magnet.
•
Hold permanent magnet over the left display (2).
The left display flashes for approx. 5 seconds.
After that measurement value 99 is saved as upper limit of measuring range.
• Remove
magnet.
Pos: 41 /Layout Module /---------------Seitenumbruch---------------- @ 0\mod_1196175311226_0.docx @ 4165 @ @ 1
Summary of Contents for Swadro TS 620
Page 136: ...1 1V1 1V2 2 1 1V3 1V1 1V2 1V3 2 1 1 2 1 2 3 4 Swadro TS 620 Swadro TS 680 Swadro TS 740 ...
Page 137: ...1 2 2 1V1 1V2 2 1 1V3 1V1 1V2 1V3 2 1 1 2 1 2 3 4 5 6 Swadro TS 620 Twin Swadro TS 680 Twin ...
Page 138: ...1 2 2 2V1 2V1 1V1 1V2 2 1 1V3 1V1 1V2 1V3 2 1 1 2 1 2 3 4 5 6 7 Swadro TS 740 Twin ...
Page 141: ......
Page 142: ...0 1 2 3 4 5 0 1 2 3 4 5 6 7 8 9 6 7 8 9 2 5 2 0 0 2 2 ...
Page 143: ...0 1 2 3 4 5 0 1 2 3 4 5 6 7 8 9 6 7 8 9 2 0 8 5 0 5 1 0 0 0 5 0 44 5 5 58 ...
Page 144: ... 2 1 6 7 8 9 1 6 7 8 9 5 3 2 1 0 4 2 3 4 5 6 0 8 7 8 5 ...