Maintenance – lubrication
271
13.8.1.3
Namur sensor d = 30 mm
a
BPXC0172
2
1
3
Figure 197
The dimension between the encoder (2) and the sensor (1) must be "a" = 5 mm
.
Setting
•
Loosen the nuts on either side of the sensor.
•
Turn the nuts until dimension "a" = 5 mm
is reached.
•
Tighten the nuts again.