![Krone Big Pack 1270 HS Original Operating Instructions Download Page 129](http://html1.mh-extra.com/html/krone/big-pack-1270-hs/big-pack-1270-hs_original-operating-instructions_2004791129.webp)
KRONE ISOBUS-Terminal CCI 100
129
Pos: 24.133 /BA/Info-Center/Großpackenpresse/Hauptmenüs/Hauptmenü 4 Service/Einstellwert Sensor B 55/56 (Kraftsensor) für HS BAureihe @ 64\mod_1300109830543_78.doc @ 579813
Sensor B55 / B56
The sensors B55 / B56 for weighing the bale on the chute are pre-set in the factory. The two
bars (1, 2) must be inside the marked area (3) of the bar display. Heavy loads and the settling of
components may give rise to the need for subsequent calibration if the bar (2) within the marked
area (3) is larger or smaller than the bar (1).
To do this:
•
Keep function key
pressed down for about 2 seconds.
The left hand bar (1) takes on the value of the right hand bar (2). The symbol
shows that
the value has been stored.
Pos: 24.134 /BA/Info-Center/Sensoren/Statusanzeigen Kraftsensor @ 19\mod_1238137064775_78.doc @ 215205
State:
Broken cable or short circuit
Defect in the sensor / force measurement amplifier or job computer
Pos: 24.135 /BA/Info-Center/CC-ISOBUS-Terminal/CCI-BiG Pack/Hauptmenüs/ESC drücken um Menü Service 4 zu schließen bzw. zum Grundbild zugelangen @ 44\mod_1275893530687_78.doc @ 393687
•
Pressing the function key
closes the called up menu
The display shows menu level 4 "Service".
•
Pressing the function key
and holding it down brings up the basic screen
Pos: 24.136 /BA/-----Seitenumbruch------ @ 0\mod_1196175311226_0.doc @ 4165