Setting the locking (frame)
Fig. 164
•
Set the support tube (10) so that the distance between the locking (11) and the support
tube (10) is Z = 15-35 mm
Pos: 32.116.8 /BA/Einstellungen/Großpackenpresse/MutiBale/Einstellung Verriegelungen der Nadelschwingen @ 24\mod_1241501736055_78.doc @ 245306
10.14.6
Setting the lockings of the needle yoke
Fig. 165
In order to ensure a safe lock of the second needle yoke (13), the locking (11) (as shown in the
figure above) has to have a distance of U = 3 – 7 mm to the pin (12) of the needle yoke (14).