2
INSTALLATION
36
OPTIFLEX X200
www.krohne.com
09/2018 - 4006564001 - AD IECEX OPTIFLEX x200 R01 en
2.3.13 OPTIFLEX 8200 S (compact converter with sensor extension version)
Maximum limits for EPL Ga/Gb, EPL Gb, EPL Da/Db and EPL Db
Maximum limits for EPL Gc and EPL Dc
Temperature
class
Maximum surface
temperature
Max. process
temperature or
process connection
temperature
Maximum ambient temperature
4-20mA / HART with
or without optional
output
Fieldbus (PA/FF)
Modbus RTU
[
°
C]
T6
T85
+60
+55
+51
+85
+55
+51
T5
T100
+75
+70
+66
+100
+70
+66
T4
T135
+110
+80
+135
+80
T3
T200
+150
+80
+180
+80
+200
+80
T2
T300
+250
+80
+280
+80
+300
+80
T1
T315
+315
+80
Temperature
class
Maximum surface
temperature
Max. process
temperature or
process connection
temperature
Maximum ambient temperature
4-20mA / HART with
or without optional
output
Fieldbus (PA/FF)
Modbus RTU
[
°
C]
T6
T85
+60
+67 (+47)
1
+67
+85
+67 (+47)
1
+67
T5
T100
+75
+80 (+62)
1
+80
+100
+80 (+62)
1
+80
T4
T135
+110
+80
+135
+80
T3
T200
+150
+80
+180
+80
+200
+80
T2
T300
+250
+80
+280
+80
+300
+80
T1
T315
+315
+80
1
Values in parentheses are for Ex ic nA-approved devices with EPL Gc