KRAMER: SIMPLE CREATIVE TECHNOLOGY
Operating the VP-81SID Locally via the Front Panel Buttons
18
8. Click
OK
.
6.5.2 Connecting via a Network Hub, Switch, or Router
You can connect the Ethernet port of the
VP-81SID
to the Ethernet port on a
network hub, switch, or router, via a straight through cable with RJ-45 connectors.
The
VP-81SID
Ethernet port has to be configured to be compatible with your
network (see
Section 8.1.13
).
7
Operating the VP-81SID Locally via the Front Panel Buttons
Powering up the
VP-81SID
recalls the last settings (that is, the configuration of the
device when it was powered down) from the non-volatile memory.
7.1 Selecting an Input
The input buttons illuminate to indicate the following:
•
Off indicates the input is not selected
•
On indicates the input is selected
•
Flashing indicates that you have tried to select the input but another input
with a higher priority is currently selected
To select an input:
•
Press one of the ten front panel Input Select buttons. The selected button
lights
Note
: Pressing an active input button mutes the input. Pressing the button again
unmutes the input.
Note
: The priority of each input can be set individually using the Step-In
Commander panel.
7.2 Muting the Input when using Step-In Commanders
To mute and unmute the input when using a Step-In Commander:
1. Press the Input Select button on the Step-In Commander.
The input is selected and the buttons lights.
2. Press the Step In button on the Step-In Commander.
The input is muted and the button no longer lights.
3. Press the Step In button on the Step-In Commander a second time.
The input is unmuted and the button lights.
7.3 Resetting all Input Priorities to the Default
To reset all input priorities to the default priority (10):
1. Press the Lock button until the button lights.
The front panel buttons are locked.
im Vertrieb von CAMBOARD Electronics
www.camboard.de
Tel. 07131 911201