36
OPERATING INSTRUCTIONS
SP-41-L MANUAL REV#2 OCT 2017
Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces
10.8.8 Fan Speed Control (optional)
Fan speed can be adjusted through (6) speeds. To activate this
function,
1. Press the mode key to index to the fan control icon.
2. Press the up or down arrow keys to turn on, off, or to adjust
fan speed.
Thermostat mode:
Fan(s) have a (5) minute delay time when the
fireplace is let. This allows time for heat to build in fireplace before
fan operation. The fan will continue to operate for approximately
(12) minutes after the fireplace has been turned off.
Manual mode:
Fan(s) will operate at previous setting. There is no
delay in start up or stop time.
10.8.9 Accent Light Kit (if applicable)
The light intensity can be adjusted through (6) levels.
1. Press the mode key to index to the light icon.
2. Press the up or down arrow keys to adjust the intensity level.
3. A single ‘beep’ will confirm reception of the command.
10.8.10 Remote Control Low Battery Detection
Remote control battery lifespan depends on various factors
including battery quality, number of ignitions, changes to room
thermostat set point, etcetera.
• When the remote control battery are low, a battery icon will
appear on the LCD display before all battery power is lost.
• When the batteries are replaced, this icon will disappear.