12
FRAMING
SP-41-L MANUAL REV#2 OCT 2017
Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces
3.3 Clearances to Combustibles
Table 3.1, Minimum Appliance Clearances to Combustible Material
From appliance top stand-off brackets
0 in
0 mm
From facing material 1” (25 mm) stand-off flange
0 in
0 mm
From appliance back stand-offs
0 in
0 mm
From appliance corners
1/4 in
6 mm
From appliance front
36 in
914 mm
From appliance top to ceiling
25 in
653 mm
A 45° projection from appliance sides
0 in
0 mm
Appliance sides to adjacent sidewall
4-1/2 in
114 mm
Fireplace enclosure floor to 3/4 in (19 mm) trim
37-1/8 in
943 mm
Mantel 6 in (152 mm) deep from fireplace enclosure floor
40-1/2 in
1030 mm
Minimum height of fireplace enclosure
47-1/4 in
1200 mm
Figure 3.2, Clearance to Combustibles
1”
(25mm)
4
½
”
(114mm)
13
5⁄8
”
(348mm)
6”
(152mm)
40
½
”
(1030mm)
¾
” TRIM
(19mm)
37
1⁄8
”
(943mm)
15
½
”
(393mm)
38
¾
”
(985mm)
47
¼
”
(1200mm)
45
5⁄8
”
(1158mm)
16
3⁄8
”
(416mm)
1”
(25mm)
6”
(152mm)
40
½
”
(1030mm)
¾
” TRIM
(19mm)
37
1⁄8
”
(943mm)
15
½
”
(393mm)
CLEARANCES TO COMBUSTIBLES - RIGID PIPE
CLEARANCES TO COMBUSTIBLES - FLEX PIPE