Commissioning/configuration
© 2022 KOSTAL Solar Electric GmbH
61
6.4 Settings for bank 1
The following settings can be configured via bank 1:
Configurable functions:
Bank
DIP switch
Function
1
1
No function (set to OFF)
2
Unbalanced load limitation between the phases
3
No function (set to OFF)
4
Activate Modbus RTU
5
Wallbox control, master/slave
6
Activate KOSTAL Smart Energy Meter
7
Activate convenience functions (e.g.
Solar Pure Mode
) for
KOSTAL Smart Energy Meter
8
No function (set to OFF)
Setting unbalanced load limitation
The unbalanced load monitoring between phases L1-L3 can be activated. If the unbalanced
load between the phases is greater than 4.6 kVA, the charging power is reduced. In some
countries, activation of this function is mandatory.
Configure the setting as desired.