Commissioning/configuration
© 2022 KOSTAL Solar Electric GmbH
59
6.3 Example of DIP setting depending on
application
NOTE
Bank 2 (S2):
If the values for your installation deviate from this example, e.g. for a house
connection fuse of only 50 A, this must be adapted using the DIP switches.
Settings for
bank 2 (S2)
in this example:
■
The maximum charging current per phase is set to
16 A
(bank 2 / DIP 1-3).
■
The maximum current for the house connection is set to
63 A
(bank 2 / DIP 6-8).
ENECTOR without energy meter