28
In daily schedule CH circuit and DHW cylinder have defined starting time (3) and finishing time (4) of maintaining selected temperature
value (5) in the room (CH) or DHW cylinder. Outside defined time frames economy temperature will be maintained in the room/
cylinder. For circulation circuit within the schedule there is an adjustment of start time (3) and finish time (4) of circulation pump’s
operation. In buffer mode there is an adjustment of start time (3) and finish time (4) of buffer’s charging. To change the parameters
for the daily schedule select chosen program number and press navigation dial.
The first parameter flashes (start time) - use the navigation dial to set the new time frame value (hour and minutes separately) by
turning the dial left/right and confirm it by pressing the dial again. At the same time next screen starts to flash allowing edition of
next parameters (finish time). Last editable position is a command. In order to save changes select command
and press the
dial to finish editing. To delete selected time frame start editing chosen time frame and by pressing the dial go to command
position, select command and press the dial.
DAILY SCHEDULE:
1 - time period panel
2 - no. of time frame according to schedule (max 5)
3 - start time
4 - finish time
5 - temperature selection (CH and DHW cylinder)
6 - command (active when editing):
accept
delete
add
To add new time frame, select last defined time frame and by pressing the dial go
to command position, select command and press the dial to add new time frame
(edition of new time frames described above).
The entire day program is saved in the controller’s memory when you exit the day
program by pressing the "Save and exit" command.
Protection against frost
In the standby and summer modes, if the room temperature falls below 7°C, the central heating circuit will be activated.
A TR sensor is required to activate the function.
CH program No3
CH program No3
End
End
1 0:00 - 23:59
CH program No1
CH program No1
1 6:00 - 9:15
1 6:00 - 9:15
2 15:20 - 22:15
2 15:20 - 22:15
End
End
CH program No1
CH program No1
1 6:00 - 9:15
2 15:20 - 22:15
2 15:20 - 22:15
2
3
4
5
6
1
End
End
Summary of Contents for HPMI2 - 12