24
1 - no. of time frame according to schedule (max 5)
2 - start time of circulation pump operation
3 - finish time of circulation pump operation
-
No. 1...No. 8 > setting 8 daily programs. In each daily program there are 5 editable time frames, which can have one of the
room temperature sets (
,
).
In any other case, the economy temperature will be activated (
).
Setting up daily programs procedure is described in
Daily Schedule
paragraph.
-
WEEKLY: assigning for each week day one of the previously set daily programs.
•
Circulation program (available only within active circulation in system DHW)
-
No. 1 ... No. 8> setting of 8 daily programs in each daily program. There are 5 adjustable time intervals in which it will work
circulation pump
Setting up daily programs procedure is described in
Daily Schedule
paragraph.
-
WEEKLY: assigning for each week day one of the previously set daily programs.
• DISINFECTION (only available in systems with DHW):
-
WEEK DAY: the day for disinfection during.
-
TIME: the time it takes to disinfect with automatic program.
-
WORKING TIME: time of disinfection (calculated from the moment the temperature has reached disinfection).
-
AUTOMATIC WORK:
Yes - automatic work start of disinfection at the set time (time, day of the week, beginning time)
No - automatic disinfection turned off. Disinfection is carried out at the user's demand.
-
CIRCULATION: it is possible to set disinfection of the entire installation or only DHW.
-
ACTIVATE NOW: manual start of disinfection (independent of the day’s or time’s set).
•
Cooling program (only available with active plane cooling)
-
No.1 ... No.8 setting 8 daily programs, in each daily program there are 5 adjustable time intervals in which the colling mode
is performed.
/ the procedure for setting the daily programs is described in the Daily Schedule section /.
-
Weekly: assigning to each day of the week one of the preset daily programs.
•
TIME / DATE:
-
setting of the current system time (YEAR / MONTH/ DAY / HOUR / MINUTE).
-
AUTOMATIC TIME CHANGE:
Yes - automatic system time changeover from summer to winter and vice versa,
No - automatic change turned-off
Attention, in case of cooperation with the Internet module, automatic time change should be switched off.
Circulation program No1
Circulation program No1
Koniec
Koniec
1 6:00 - 8:00
2 18:30 - 23:00
2 18:30 - 23:00
1
2
3
1 - time interval number (max. 5)
2 - cooling function start time
3 - cooling function completion time
Koniec
Koniec
1 6:00 - 8:00
2 18:30 - 23:00
2 18:30 - 23:00
1
2
3
Cooling program No1
Cooling program No1
Summary of Contents for HPMI2 - 12