Troubleshooting Programs and Combinations
65
discontinuities
in
the
delay
sound,
and
is
not
a
malfunction.
Some
effects,
such
as
S19:
St.Record,
generate
noise
intentionally.
It
is
also
possible
to
make
a
resonant
filter
oscillate.
Please
check
the
settings.
Note
that
if
you
use
the
following
effects
with
the
routing
described
below,
a
feedback
loop
will
be
created,
possibly
producing
a
loud
noise.
Please
use
caution.
If
the
signal
from
an
oscillator
or
timbre/track
output,
or
the
signal
after
an
insert
effect,
is
sent
to
the
FX
Control
bus
and
that
signal
is
output
directly,
with
this
output
sent
to
the
FX
Control
bus,
a
loud
noise
may
be
output.
(It
is
also
possible
that
a
DC
component
will
be
output
at
the
maximum
level,
producing
silence.)
• When
using
S03:
St.Limitr
or
S06:
St.Gate,
and
the
“Env
Sel”
of
these
effects
is
set
as
either
FX
Ctl1
or
FX
Ctl2,
and
“Trigger
Monitor”
is
On
(editable
only
by
using
microSTATION
Editor
/
Plug
‐
In
Editor).
• When
using
D09:Vocoder,
and
the
“Mod
Src”
of
this
effect
is
set
as
either
FX
Ctl1
or
FX
Ctl2,
and
“Modulator
High
Mix”
is
set
to
other
than
0
(editable
only
by
using
microSTATION
Editor
/
Plug
‐
In
Editor).
Can’t play chords
Could
the
program’s
Voice
Assign
Mode
be
set
to
Mono?
PG
p. 3
Pitch is incorrect
In
the
Global/Media:
Basic,
are
the
MTune
and
Transpose
settings
correct?
PG
p. 57
In
the
Prog
Edit:
OSC1
or
OSC2,
is
the
PitchSlope
set
to
+1.0?
PG
p. 7
In
the
combination
or
song,
are
the
Transpose
and
Detune
settings
of
each
timbre/track
set
appropriately?
PG
p. 20,
PG
p. 39
Programs and Combinations
Settings for oscillator 2 are not displayed
Have
you
selected
a
program
that
uses
oscillator
2?
Program does not sound
Could
the
oscillator
or
amp
level
be
lowered?
PG
p. 7
Is
the
oscillator’s
“Play/Mute”
parameter
set
to
Play?
A combination does not play correctly after
you load data
Are
the
category
and
index
number
of
the
programs
used
by
the
combination
the
same
as
when
you
created
the
combination?
Can’t write a Program
Is
the
Memory
Protect
Program
or
Combi
off
(GLOBAL/MEDIA:
Basic)?
PG
p. 60
Songs
The sound of the program selected for a
track is different than when played in
Program mode
When
you
select
a
program
for
a
track
in
Sequencer
mode,
the
arpeggiator
and
effect
settings
of
Program
mode
are
not
assigned
automatically.
You
can
use
the
SEQ
EDIT
command
“Copy
ARP,”
“Copy
IFX,”
or
“Copy
MFX/TFX”
etc.
to
copy
the
Program
mode
settings.
PG
p. 48
Song does not play correctly after being
loaded
Are
the
programs
used
by
the
song
the
same
as
when
the
song
was
created?
When
saving
the
song,
it
is
best
to
use
Save
All
so
that
the
programs
are
saved
together
with
the
song.
Then
when
loading,
load
both
the
.PCG
and
the
.SEQ
data.
PG
p. 69
Playback does not start when you press the
Start/Stop button in Sequencer mode
Is
the
Clock
(Global/Media:
MIDI–MIDI
Clock)
set
to
Internal
or
Auto?
PG
p. 62
Can’t record in Sequencer mode
Did
you
select
the
MIDI
track
that
you
want
to
record?
Is
the
Memory
Protect
Song
off
(Global/Media:
Basic)?
PG
p. 60
Is
the
Clock
(Global/Media:
MIDI–MIDI
Clock)
set
to
Internal
or
Auto?
PG
p. 62
When
using
loop
recording,
could
you
be
in
Rehearsal
mode?
Turn
off
Rehearsal
mode.
After using the song command “Copy
Combi” to copy a combination, you can’t
record the arpeggiator as when you were
playing that combination
Were
the
settings
correct
when
you
executed
Copy
Combi?
In
the
Copy
Combi
settings,
set
“Multi
Rec?”
to
Yes
before
you
execute
the
copy.
These
settings
will
be
made
automatically.
Can’t record program changes
Is
the
MIDI
filter
“Prog
Chg”
turned
On
for
each
track?
This
is
Off
by
default.
Turn
the
MIDI
filter
“Prog
Chg”
On
for
each
track
before
you
record.
Can’t record changes in tone parameters
Tone
parameters
are
recorded
as
system
exclusive
data.
Is
the
Global/Media
mode
MIDI
Filter
“SysEX”
turned
On?
This
is
Off
by
default.
PG
p. 63