TIGW1U server—Server Installations and Upgrades
Kontron Carrier Grade Server TIGW1U
Product Guide, rev. 1.3
December 2009
68
2. Remove the adhesive cover from the bottom of the insulator.
Place the insulator around the battery, lining up the hole with the riser card
assembly hole. See
Figure 56
.
3.6
Installing the Server into a Rack
Installation instructions for the standard bracket kit and the optional rail kit are
included with each kit. These instructions can also be found on the Kontron Deployment
Assistant CD and at
http://us.kontron.com/support/.
Search for TIGW1U.
3.6.1
Connecting the Power Cord
Note:
When placing your server in a rack, wait to install the power cord until after the server
is in the rack.
3.6.2
Equipment Rack Precautions
Caution:
ANCHOR THE EQUIPMENT RACK:
The equipment rack must be anchored to an
unmovable support to prevent it from falling over when one or more servers are
extended in front of it on slide assemblies. The equipment rack must be installed
according to the manufacturer's instructions. You must also consider the weight of any
other device installed in the rack.
Mains power disconnect:
The power cord(s) is considered the mains disconnect for
the server and must be readily accessible when installed. If the individual server power
cord(s) will not be readily accessible for disconnection then you are responsible for
installing an AC power disconnect for the entire rack unit. This main disconnect must be
readily accessible, and it must be labeled as controlling power to the entire rack, not
just to the server(s). To remove all power, two power cords must be removed.
Grounding the rack installation:
To avoid the potential for an electrical shock
hazard, you must include a third wire safety ground conductor with the rack
installation. If the server power cord is plugged into an outlet that is part of the rack,
then you must provide proper grounding for the rack itself. If the server power cord is
Figure 56.
Attaching the Battery Insulator
TS000418
A
B