Kontron Carrier Grade Server TIGW1U
December 2009
Product Guide, rev. 1.3
53
Server Installations and Upgrades—TIGW1U server
4. Connect the power and data cables back onto the interposer board.
5. If this is the only change you are making, attach the front bezel and cover and
reconnect the power to the chassis.
3.5.2
Replacing a Fan Assembly
Caution:
Your server does not have hot-swappable fans. Before replacing any of the fans, you
must first take the server out of service, turn off all peripheral devices connected to the
system, turn off the system by pressing the power button, and unplug the AC power
cord from the system or wall outlet.
The replacement/spare fan set consists of one PCI fan and four dual-rotor CPU fans
plus enough resilient fan bumpers for all five fans. The bumpers are used to isolate fan
vibration from the rest of the system.
Figure 41.
Installing the Drive Tray with Optical Drive Attached into the Server
A
B
TS000223
Figure 42.
PCI Fan and Four-Fan Set (with Bumpers Installed)
AF000831
A
B