TIGW1U server—Server Installations and Upgrades
Kontron Carrier Grade Server TIGW1U
Product Guide, rev. 1.3
December 2009
42
2. Set the heat sink over the processor, lining up the four captive screws with the four
posts surrounding the processor. Align the heat sink fins to the front and back of
the chassis for correct airflow (front to back). Use caution and make sure that
cables are not pinched beneath the heat sink. (See
Figure 21
.)
3. Loosely screw in or finger tighten the captive screws on the heat sink corners in a
diagonal manner. Do no fully tighten one screw before tightening another.
4. Gradually and equally tighten each captive screw until each is firmly tightened.
3.4.5
Installing or Replacing a PCI Add-in Card
The riser card assembly is installed in the super slot located in the middle of the
S5000PHB server board. (See
Figure 7
for this location.) The system is delivered with a
PCI-X* riser card attached to the riser card assembly. To use PCI Express* (PCIe*)
cards, this riser must be replaced with the PCIe riser card, which can be ordered as an
accessory.
Note:
PCI / PCI-X / PCI Express add-in cards are referred to generically as “PCI cards” in the
following procedures.
To add a PCI card, remove the riser card assembly from the system. Ensure that the
appropriate riser card is attached to the assembly (PCI/PCI-X by default) or replace it
with the correct one (e.g, PCIe instead of PCI-X), remove the I/O filler panel, then add
the PCI or PCIe add-in card. This assembly is then plugged back into the super slot
connector on the S5000PHB server board server board. Refer to the
Intel® Server
Board S5000PHB Technical Product Specification
for the electrical characteristics for the
PCI/PCIe riser card assembly super slot.
Note:
Use a supported PCI/PCIe card. For a list of tested and supported cards,see the
Tested
Hardware and Operating System List
(THOL) at
http://us.kontron.com/support/
.
Search for TIGW1U, click on Product Downloads, and then
3.4.5.1
Removing the PCI Riser Card Assembly
To remove an installed riser card assembly, follow these steps:
1. Loosen the blue captive screw that secures the riser card assembly to the server
board. (“A” in
Figure 28
)
2. Loosen the blue captive thumb screw on the rear panel of the chassis. (“B”)
3. Lift the riser card assembly straight up and remove it from the chassis. (“C”)