MAINTENANCE
SERVICE PROCEDURE
Use the diagram below for reference, and check if the electrolyte reaches the bottom of the sleeve.
3. After adding distilled water, tighten cap (3) securely.
REMARK
If distilled water is added to above the bottom of the sleeve, use a syringe to lower the level to the bottom of the
sleeve. Neutralize the removed fluid with baking soda (sodium bicarbonate), then flush it away with a large amount
of water or consult your Komatsu distributor or battery maker.
WHEN IT IS POSSIBLE TO USE INDICATOR TO CHECK ELECTROLYTE LEVEL
If it is possible to use an indicator to check the electrolyte level, follow the instructions given.
4 - 44