ACTIONS WHEN POP-UP MESSAGE IS DISPLAYED ON CONTROL BOX
Control box screen display
Main causes
Remedy
Pop-up message (screen center)
Auto Control Disengaged!
(Red)
Automatic control of blade
is turned off from on.
Press the Auto/Manual switch.
For details, see “AUTO/
MANUAL SWITCH”.
Cylinder Sensor Reset Request! Please move
the Lift cylinder to stroke end and keep it
there for 2 seconds.
(Gray)
Resetting of the stroke end
of lift cylinder is not com-
pleted.
Perform resetting of the stroke
end of cylinder. For details,
see “RESET CYLINDER
STROKE END”.
Cylinder Sensor Reset Request! Please move
the Tilt cylinder to stroke end and keep it
there for 2 seconds.
(Gray)
Resetting of the stroke end
of tilt cylinder is not com-
pleted.
Cylinder Sensor Reset Request! Please move
the Angle cylinder to stroke end and keep it
there for 2 seconds.
(Gray)
Resetting of the stroke end
of angle cylinder is not
completed.
ACTIONS WHEN Sitelink3D MESSAGE IS DISPLAYED ON CONTROL BOX
The following messages are not abnormalities but take a remedy according to the message if necessary.
Control box screen display
Main causes
Remedy
No current "activity" selected!
Please select an activity from the
Sitelink3D menu.
“Activity” of “Sitelink3D”
menu has not been set.
Press “Ok” and close the message screen.
On the control box screen, press “Sitelink3D activity”
or select “Activity” of “Sitelink3D” menu.
If the Activity is not displayed on the drop down list,
register it from the office side.
Even if performing the work without setting the Activi-
ty, it does not affect the work.
Registered name of terminal:
“Content of message”
A message is received
from the device which is
connected to the same
site of Sitelink3D.
No remedy is needed since the message display will
be cleared as time elapsed.
Check the contents of the message by pressing “Si-
telink3D messaging” on the control box screen, or on
“View messages...” of “Sitelink3D” menu.
TROUBLES AND ACTIONS