1.4.3 Ambient Conditions in normal operation
Storage, Transport
Normal operation
Environmental class 3K3 according to IEC 61800-2
Surrounding air tem-
perature in operation
0 to +40 °C under rated conditions
+40 to +55 °C with continuous current derating 4 % per Kelvin
Humidity in operation
Relative humidity 5 to 85%, no condensation, class 3K3
Site altitude
Up to 1000 meters above mean sea level without restriction
1,000 to max. 2,000 meters above mean sea level with power
derating 1.5%/100 m
Pollution level
Pollution level 2 as per IEC 60664-1
Vibrations
Class 3M1 according to IEC 60721-3-3
Environmental area
Cabinet IP 54 according to IEC 60529
Mounting position
Vertical
Ventilation
Built-in fan.
CAUTION
Continuous noise up to 60dBA during operation. Keep cabinet
doors closed during operation. To reduce inconvenience, we sug-
gest to use ear protection if cabinet doors must be opened during
normal operation.
The device shuts down in case of excessively high temperature
in the control cabinet. Make sure sufficient forced ventilation is
supplied within the control cabinet.
1.4.4 Electrical Data
Electrical data (
1.4.5 System limits
Length String 2/3
Maximum 100 m total cable length per string.
Number of MKD-C
Limited by fieldbus protocol.
Number of MKD-N
axes
Maximum 14 axes for string 1, total maximum 28 axes if string 1
and 2 are combined (observe total power and current restric-
tions).
Number of AKD-N
Maximum 14 per string, total maximum 28 on strings 2 and 3,
(observe total power and current restrictions).
Output current
Use coincidence factor of the axes for distribution and system
power optimization.
String 1: 43 A, String 2: 16 A, String 3: 16 A
Total power
At 565 V to 680 V limited to 30 kW.
String 2/3 power
At 565 V to 680 V limited to 10 kW for each string.
String standby power
At 55 V limited to 180 W for each string.
Motor Brake power
You can control up to 3 motor brakes per string. Available power
for brakes is 76 W per string (= 3.2 A @ 24 VDC).
Service Interface X18
Ethernet TCP/IP, 100 Mbit/s, max. cable distance 100 m
MKD Product Safety Guide | 1 English
Kollmorgen | kdn.kollmorgen.com | January 2019
15
Summary of Contents for MKD-C Series
Page 22: ...MKD Product Safety Guide 1 English 22 Kollmorgen kdn kollmorgen com January 2019...
Page 42: ...MKD Product Safety Guide 2 Deutsch 42 Kollmorgen kdn kollmorgen com January 2019...
Page 44: ...MKD Product Safety Guide 3 Fran ais 44 Kollmorgen kdn kollmorgen com January 2019...
Page 46: ...MKD Product Safety Guide 4 Italiano 46 Kollmorgen kdn kollmorgen com January 2019...
Page 48: ...MKD Product Safety Guide 5 Portugu s 48 Kollmorgen kdn kollmorgen com January 2019...
Page 50: ...MKD Product Safety Guide 6 Espa ol 50 Kollmorgen kdn kollmorgen com January 2019...