MKD Product Safety Guide | 8 Appendix
8.3.3 Fusing
8.3.3.1 External power supply and 24 V fusing
Non renewable cartridge fuses must be used with finger safe fuse holders according to
IEC 60529.
UL cartridge fuses
: Class J, 600 VAC 200 kA, time-delay. The fuse must be UL and CSA
listed, UL recognized is not sufficient.
CE cartridge fuses
: types gS(gRL) or gG, 400 V/500 V, time-delay
Cartridge Fuses
Ampere rating UL Region
CE Region
External AC power
supply fusing (FN1/2/3)
60 A (Time-Delay) example Mersen:
AJT 60, 60A
example Siba:
type gS/gG, D02, 63A
External 24 VDC supply
fusing (FA1)
40 A (Time-Delay) example Mersen:
TR40R, 40A
example Mersen:
D02GG40V40/10, 40A
Ampere rating for operation with full application power. Low coincidence factor may allow
reduction of fuse ampere rating.
8.3.3.2 External regen resistor fusing
FPS: Frizlen DC Powerswitch
RBext
FPS
Range [In]
cable cross section
BAS(U)2000-10
FPS-16
10 to 16 A
min. 2.5 mm²
BAS(U)3000-10
FPS-20
16 to 20 A
min. 4 mm²
BAS(U)6000-10
FPS-25
20 to 25 A
min. 4 mm²
8.3.3.3 DC-Bus link fusing
DC Bus sharing functionality is pending. Do not use this functionality until further notice.
64
Kollmorgen | kdn.kollmorgen.com | January 2019
Summary of Contents for MKD-C Series
Page 22: ...MKD Product Safety Guide 1 English 22 Kollmorgen kdn kollmorgen com January 2019...
Page 42: ...MKD Product Safety Guide 2 Deutsch 42 Kollmorgen kdn kollmorgen com January 2019...
Page 44: ...MKD Product Safety Guide 3 Fran ais 44 Kollmorgen kdn kollmorgen com January 2019...
Page 46: ...MKD Product Safety Guide 4 Italiano 46 Kollmorgen kdn kollmorgen com January 2019...
Page 48: ...MKD Product Safety Guide 5 Portugu s 48 Kollmorgen kdn kollmorgen com January 2019...
Page 50: ...MKD Product Safety Guide 6 Espa ol 50 Kollmorgen kdn kollmorgen com January 2019...