11.3.1
Frame size, flange and shaft options
Dimension drawings can be found from page 62.
Frame
size
Flange
type
Flange
diameter
Pilot
diameter
Shaft
diameter
Accuracy
pilot
1)
Accuracy
shaft
2)
Tolerance class
pilot
3)
2
A, C
Æ
79 mm
Æ
40 mm
Æ
11 mm
j6
k6
N
3
A, C
Æ
89 mm
Æ
60 mm
Æ
14 mm
j6
k6
N
4
A, C
Æ
114 mm
Æ
80 mm
Æ
19 mm
j6
k6
N
5
A, C
Æ
148 mm
Æ
110 mm
Æ
24 mm
j6
k6
N
6
A, C
Æ
186 mm
Æ
130 mm
Æ
32 mm
j6
k6
N
1) acc. to EN 60034-7
2) acc. to EN 42955
3) acc. to EN 50347
Flange mounting (flange types Ax, Bx):
The basic style for flange mounting is style IM B5 according to EN 60034-7.
Mount the FDA approved o-ring (part of mounting kit) for flange sealing.
Face mounting (flange types Cx, Dx):
The basic style for face mounting is style IM B14 according to EN 60034-7
.
Mount the FDA approved o-ring (part of mounting kit) for flange sealing.
Shaft
Power transmission is made through the cylindrical shaft end (with a shaft center thread).
Code
Description
Remarks
C
Closed keyway
Keyway according to DIN 748.
Key according to DIN 6885 T1 form A.
Key material: stainless steel 1.4404
N
Smooth shaft
-
Servomotors AKMH
English - 39
Kollmorgen
08/2013
Package
ENGLISH
IM B 5 (B5)
IM V 1 (V1)
IM V 3 (V3)
IM B 14 (B14)
IM V 18 (V18)
IM V 19 (V19)