4. Remove the fan by removing the two M4x35 Torx screws.
Figure 4-2:
A. Screw, M4x35 Torx
B. Fan
5. Reassemble with new fan and
fi
lter in reverse order. Use a maximum torque of 0.4 Nm when
fastening the fan screws.