AKD2G-S Installation Manual, Safety 1 | 8 Electrical Installation
8.6.1.1 Wiring examples mains power supply
One phase AC mains (AKD2G-Sxx-6V)
Directly to one phase supply network with neutral line.
Activate single phase supply (VBUS.THREEPHASE = 0).
Set VBUS.ACNOMINAL to desired nominal AC line voltage for lines other than nominal
rated VAC.
AC line filtering to be provided by the user. Use filter type FN2090, refer to the
Accessor-
ies Manual
for more information. Use shielded cable between filter and drive.
Two phases AC mains (AKD2G-Sxx-6V)
Directly to two-phase supply network without neutral line.
Activate single phase supply (VBUS.THREEPHASE = 0).
Set VBUS.ACNOMINAL to desired nominal AC line voltage for lines other than nominal
rated VAC.
AC line filtering to be provided by the user. Use filter type FN2090, refer to the
Accessor-
ies Manual
for more information. Use shielded cable between filter and drive.
68
Kollmorgen | kdn.kollmorgen.com | July 2020