SC-021/RC-010 Introduction Manual /Practical Version
40
Md
PE
Ax
Sp
Val
E N C C A L
D I V
1 / N
2 4
:
1
0 0 0 0 0 0 0 1
Md
PE
Ax
Sp
Val
E N C C A L
D I V
1 / N
2 4
:
1
N N N N N N N N
Md
PE
Ax
Sp
Val
S T A R T S P E E D ( p p s )
0 1
:
1
0 0 0 0 0 5 0 0
Md
PE
Ax
Sp
Val
E N C C A L
D I V
1 / N
2 4
:
1
0 0 0 0 0 0 0
1
5.
Converting Encoder Value to Real Distance/Angle
《
Setting Conversion Coefficient
》
System Setting Items 24 & 25
(A) Setting Conversion Coefficient Denominator
(System Setting Item 24)
ⅲ)
Using the keypad, enter the desired coefficient denominator.
ⅳ)
Press “
SET
” button again when finished.
ⅰ
)
Change setting item number to
“No.24”
at system setting status by moving dial-key up or down.
ⅱ
)
Press “
SET
” button to access
data entry screen
.
Dial-key moving up or down
Press ”SET”
Press ”SET”
Fix the setting
Enter
coefficient
denominator
Change setting item
Into data entry
Input number
This process allows operator to convert encoder value into real travel distance/angle. Process
must be completed prior to changing display data, explained on pages 50-52.
Caution: The default setting for the number of digits to be displayed is set to (2). Conversion
results that exceed two digits will be displayed incorrectly. To increase the number of digits
displayed, see page 39 “Setting Number of Displayed Digits”.