![Kohzu Precision RC-010 Manual Download Page 29](http://html1.mh-extra.com/html/kohzu-precision/rc-010/rc-010_manual_1990247029.webp)
SC-021/RC-010 Introduction Manual /Practical Version
25
No.
Display on LCD
Functional description
Default
27 ENC
PRESCALE
Setting of zero clear position when high speed table is
used
0
28
ENC RND OFF 0-9
Setting of display valid digit number of displayed value
after angle conversion
2
29 FEEDBACK
TYPE
0-2
Setting of encoder correcting method
0: No correction 1: Correction only in positioning
2: Constant correction
0
30 PERMIT
RANGE
PULSE
Setting of allowable range pulse amount when encoder is
corrected
1
31 RETRY
COUNT
Setting of retry number when encoder is corrected
100
32 WAIT
TIME
(1ms)
Setting of stop standby time before encoder is corrected
100
33 ENC
ROTATE
CHANGE
Setting of adding direction of encoder count
0
34 PM&ENC
SYNC
WRITE
Setting of encoder coordinate synchronization
0
35 SPD
TABLE
1-300
Setting of speed table rewriting
1
36 SYS
Refresh!!
Execution of system initialization
0
37 Line-1
Edit
Axis
Setting of axis No. on first line on LCD panel
1
38
Line-1 Edit P E
Setting of conversion display on first line
0: Pulse
non
converted display
1: Pulse converted display
2: Encoder
non
converted display
3: Encoder converted display
0
39 Line-2
Edit
Axis
Setting of axis No. on second line on LCD panel
2
40
Line-2 Edit P E
Setting of conversion display on second line
0: Pulse
non
converted display
1: Pulse converted display
2: Encoder
non
converted display
3: Encoder converted display
0
41
Manual Hi Speed
Speed table No.
Set by “
SET
” button at
scan mode operation
7
42
Manual Lo Speed
Speed table No.
Set by “
CLR
” button at
scan mode operation
1
43 Scan
Pulse
Val
Setting of pulse value driven by pressing just one time at
scan mode operation
1